- for galvanic isolation between the ball immersion switches used in the Ex area and a control system
- The auxiliary switching device places the immersion switches or other control devices in 'intrinsically safe circuits' of protection class EEx ib IIC.
- because only the control circuits are intrinsically safe
- The device must be installed outside of the explosion hazard area.
- Controller for 1N/PE x 230 V
- 50 Hz operating voltage
- consisting of 1 ISO housing with clear lid
- IP 54 (HxWxD) 180 x 130 x 100 mm
- with PG screw connections H= 220 mm 1x auxiliary switching module Ex II (with 2 intrinsically safe circuits)
- 1x sticker for marking intrinsically safe cables
- The auxiliary switching device requires its own power supply.
- In the event of a mains power failure, the transmission of a switching command is therefore only possible via the battery available as an accessory.
- Connection options and integrated charging circuitry are already included as standard.
- A battery must also be used in the downstream control unit for the alarm system to be powered independently of the mains.
Jung Pumpen auxiliary switching device JP16720 180 x 130 x 100 mm, for separation
Details
Notice
Please note that gas and electric appliances require increased mains voltage for proper operation. These appliances are not equipped with a two-pin mains plug. The installation of non-pluggable appliances must be carried out by the respective network operator or a certified specialist company, which can also assist you in obtaining any necessary approval from the relevant network operator for the installation of the appliance.