Attention: accumulator pressure maximum 8 bar
DHW heat pump combination device consisting of an air-water heat pump with active defrosting and enamelled hot water tank, as well as a tube bundle heat exchanger for connecting additional energy generators. Recirculated air or outside air operation through rotatable 160mm air connections for installation without crossing.
Intuitive control with a large display, self-learning control for the optimum storage tank temperature or manual operating modes ECO active and ECO inactive (allows heating element), holiday mode, PV function via setpoint increase, frost protection function.
Hot water tank with diamond-quality enamel and active corrosion protection through ACI external current anode (no regular replacement necessary) and built-in steatite dry heating.
Heat pump with COP 3.8 at A20W10-53
Refrigerant safety heat exchanger (external)
Automatic defrost
Smart control self-learning temperature adjustment
timer function
Photovoltaic function, SG ready
large display with consumption statistics
enameled steel storage
ACI hybrid impressed current anode
Steatite heating element (1.8 kW)
holiday function
Anti-Legionella mode (periodic heating)
Can be transported lying down (supine position see box)
data storage
Storage capacity: 200 L
Accumulator operating pressure 6 bar (recommended)/max. 8 bars
Safety valve recommended 6 bar
(not included)
Operating temperature register: max. 110°C
For boiler operation rec. Storage temperature 65°C max.
Water connections (hot/cold/circulation): 3/4"
Heater Connections: 1"
Dimensions including insulation (H x W/D) mm: 1617 x Ø 620 / 665 mm
Tilt dimension: 1740 mm
Minimum room height: 1700 mm
Weight : 97 kg
Heating surface: 1.2 m²
Energy efficiency class: A+
Heat pump data:
Power consumption: max. 700 W / 2500 W*
Heating rod*: 1800 watts
Voltage/Frequency: 230V/50Hz
COP (EN 16147): 3.8 ((A20/W10-55;XL)
Refrigerant charge: R513a / 0.86 kg
Hot water temperature: heat pump operation 62°C
Necessary air volume flow: 310/390 m³/h
Air temperature: -5°C to max. +43°C
Sound power level: 53dB(A)
Included in delivery: condensate drain hose, 2 pieces of adjustable feet, 1 piece of galvanised. separator.